This article advises how I have replaced a Mira Shower thermal switch in a MIRA Sport 9kW Thermostatic Shower on several occasions.

Originally I installed a MIRA Sport 9kW Thermostatic Shower as part of a new bathroom and had it tested and certified by a qualified electrician on 1st May 2007. I was very pleased with it and it worked well for three years until June 2010 when it developed a fault.

I found that in the middle of taking a shower the water would go cold for a few seconds and then get warm again. On the first few occasions I wondered if cold water being drawn off by other taps and appliances was lowering the water pressure to the shower and so causing it to operate incorrectly (although the low pressure light was not illuminating). As the days went by the problem got worse and my wife ended up washing shampoo off with cold water. I knew then that I would be in bad books until it was fixed.

I had to determine if this fault could be fixed or if I would have to replace the entire shower unit. For this I needed to take a look inside the shower unit.

Continue reading “Mira Shower Thermal Switch Replacement”